» » IAEA Quality Control Atlas for Scintillation Camera Systems

Free eBook IAEA Quality Control Atlas for Scintillation Camera Systems download

by Not Available

Free eBook IAEA Quality Control Atlas for Scintillation Camera Systems download ISBN: 9201013035
Author: Not Available
Publisher: Intl Atomic Energy Agency; 1 edition (June 5, 2003)
Language: English
Pages: 293
Category: Other
Subcategory: Medicine and Health Sciences
Size MP3: 1930 mb
Size FLAC: 1483 mb
Rating: 4.1
Format: doc rtf mobi lit


INTERNATIONAL ATOMIC ENERGY AGENCY, IAEA Quality Control Atlas for Scintillation . The examples are not limited to the quality control tests.

INTERNATIONAL ATOMIC ENERGY AGENCY, IAEA Quality Control Atlas for Scintillation Camera Systems,, IAEA, Vienna (2003). Download to: EdNote BibTeX use BibTeX for Zotero. This book presents numerous examples which allow the reader to gain an understanding of the interpretation of quality control tests and to recognize artefacts. The examples are not limited to the quality control tests, but include clinical images obtained from unsuspected malfunctioning in the scintillation camera and/or computer system, suboptimal use of the system or operator error.

INTERNATIONAL ATOMIC ENERGY AGENCY, IAEA Quality Control Atlas for . Accurate interpretation of Nuclear medicine image data depends upon an understanding of image patterns and quantitative results. The examples are not limited to the quality control tests, but include clinical images obtained from unsuspected malfunctioning in the scintillation camera and/or computer system, sub optimal use of the system or operator error.

PDF, TXT or read online from Scribd

PDF, TXT or read online from Scribd. IAEA Library Cataloguing in Publication Data IAEA quality control atlas for scintillation camera systems,. Vienna : International Atomic Energy Agency, 2003. p. ; 24 cm. STI/PUB/1141 ISBN 9201013035 Includes bibliographical references. Some image patterns are generic to any scintillation camera system, while others may be specific to a particular vendor system and depend on system design and corrections applied in image formation. New developments in imaging instrumentation and clinical procedures will introduce other variants.

For this scintillation camera system, an energy specific uniformity correction is needed for each radionuclide used. More usually there would be translation between successive views, so that the artefact would be more easily seen.

to the. International Atomic IAEA quality control atlas for scintillation camera s. .Pdfdrive:hope Give books away.The Certified Quality Manager Handbook With Supplemental Section (Asq). 13 MB·4,360 Downloads·New! The Quality Management Division of the American Society for Quality has put together the ultimate. strengthening of the quality control awareness of nuclear medicine specialists Quality assurance. quality assurance/quality control. 53 MB·6,298 Downloads. actions specified in Contractor's QA/QC Plan have been implemented. No Owner's QC testing of all.

This is performed with a line or point source. The spatial resolution (FWHM) in the tomographic images should be compared with a planar image at the same distance as the average radius of rotation. The loss of resolution in tomographic studies should not exceed 10%. Test is performed for checking the COR offset calibration of the system. Checking COR offset line source or point source is used, centered between two head of Spect. Error in one Head Results: In both sinograms (TL and BL), the lower half and upper part.

First Online: 16 April 2004. European Journal of Nuclear Medicine and Molecular Imaging. for the whole of 2019. Rent this article via DeepDyve. Learn about institutional subscriptions.

Author IAEA, International Atomic Energy Agency. ISBN13: 9789201013033. More Books . ABOUT CHEGG.

The examples are not limited to the quality control tests, but include clinical images obtained from unsuspected malfunctioning in the scintillation camera and/or computer system, suboptimal use of the system or operator error. Format Paperback 293 pages.

The IAEA Quality Control Atlas for Scintillation Camera Systems is.

The IAEA Quality Control Atlas for Scintillation Camera Systems is intended to complement this publication. The Atlas provides many image examples of normal and abnormal quality control tests and should be consulted when performing the tests described here. This publication focuses on the scintillation camera system, both in single and multiple head configurations, for obtaining images and quantitative data in planar imaging mode, whole body imaging mode and single photon emission computed tomography (SPECT).

Accurate interpretation of nuclear medicine image data depends upon an understanding of image patterns and quantitative results. This book presents numerous examples which allow the reader to gain an understanding of the interpretation of quality control tests and to recognize artefacts. The examples are not limited to the quality control tests, but include clinical images obtained from unsuspected malfunctioning in the scintillation camera and/or computer system, suboptimal use of the system or operator error.